Industrial UPS | 300kVA
Netcon Offers low-frequency systems that ensure compatibility with various loads, providing higher reliability and efficiency Commonly used in critical applications like data centers, medical facilities, and industrial environments, low-frequency UPS features include higher power capacity compared to highfrequency units, greater surge capacity for sudden power demands, improved voltage regulation for stable and clean power supply, and enhanced reliability to withstand harshconditions. These systems are preferred in applications where reliability, capacity, and load compatibility are essential.
| Name | Certificate |
|---|---|
| Note | View Certificate |
| INPUT | |
|---|---|
| Operating frequency range (Hz) | 50/60 (±0.05%) |
| Power factor | ≥0.97 |
| Operating voltage range (Vac) | 380/400/415 Vac (±25% ~ +20%), (3Ph + PE) |
| OUTPUT | |
| Efficiency (%) | 93 |
| Output voltage (Vac) | 380/400/415 Vac (±1%), (3Ph + N + PE) |
| Crest factor | 3:1 |
| Harmonic distortion (THDv) | ≤1 (Linear load) |
| Output frequency (Hz) | 50/60 (±0.05%) |
| PHYSICAL | |
| Shipping weight (kg) | 1690 (6P) / 2545(12P) |
| Dimension W*D*H (mm) | 1400×1000×1900 (6P) 1640×1000×1900 (12P) |
| Net weight (kg) | 1560 (6P) /2395(12P) |
| ENVIRONMENT | |
| Noise level (dB) | <72 |
| Operating Temperature (ºC) | 0 ~ 40 |
| Altitude (m) | <1500 |
| Humidity range (%) | 0 ~ 95 |
| Storage temperature (ºC) | -25 ~ 55 |
| SYSTEM FEATURES | |
| LCD display | I/O voltage, frequency, power, PF, battery status, UPS status, load %, history record |
| LED display | Input, Inverter, Bypass, Battery, Output, Status |
| Communication interface | RS232, RS485, EPO, Dry contact (optional), SNMP (optional) |
| Optional | Harmonic filter, SNMP, LBS cables, battery temperature sensor, bypass current-sharing inductor |
| Transfer time (ms) | 0 |
| Overload | ≤110%/60min; ≤125%/10min; ≤150%/1min → Bypass |
| Technical | |
| Rated voltage (Vac) | 380/400/415 Vac, (3Ph + N + PE) |
| Capacity (kVA/kW) | 300/270 |
| Rated frequency (Hz) | 50/60 (±0.05%) |
| Voltage protection range (%) | Upper: +20% (+10%, +15%, +20% adjustable); Lower: -40% (-10%, -20%, -30%, -40% adjustable) |
| Battery voltage (Vdc) | 384 |
| Frequency protection range (%) | ±10 % (±2.5%, ±5%, ±10%, ±20% adjustable) |
| STANDARDS | |
| Safety | IEC/EN 62040-1; IEC 62477-1 |
| EMC | IEC/EN 62040-2 (IEC 61000-4-2, 61000-4-3, 61000-4-4, 61000-4-5, 61000-4-6, 61000-4-8, 61000-4-11, 61000-2-2) |
| Performance | IEC/EN 62040-3 |