10-40 KVA 3:3, 3:1 | 10KVA / 10KW
Netcon 10 KVA 3:1 Phase Tower Mount Online UPS is a high-capacity, industrial-grade power backup system designed for large-scale critical applications. With a 3-phase input and 3-phase output configuration, it ensures balanced power distribution, high efficiency, and continuous protection for mission-critical systems in data centers, healthcare, telecom, and industrial operations. UPS is CE Certified and fully compliant with EMC & IEC safety and performance standards, ensuring global compatibility, safety, and reliability.
Powered by True Online Double Conversion Technology, it delivers uninterrupted, pure, and stable power with zero transfer time, ensuring complete protection against power fluctuations, surges, and blackouts. The External Battery Type design allows for the connection of scalable battery banks, offering customizable and extended backup times to meet specific operational needs. Its advanced protection features, high efficiency (up to 95%), and scalable runtime make it a trusted power solution for industries where power continuity is critical.
This UPS offers customizable backup duration, flexible battery expansion, and smart remote monitoring, making it a versatile choice for large-scale, power-intensive applications in data centers, healthcare, telecom, industrial automation, and commercial buildings.
| MODEL | |
|---|---|
| Capacity | 10KVA / 10KW |
| INPUT | |
| Harmonic distortion (THDi) | <=3% Linear load |
| Frequency Protection Range | 50/60Hz±10% |
| Frequency Range | 0-70Hz (50/60Hz Auto Sensing) |
| Voltage Range | 208-478 VAC (Full load): 120-276VAC (50% load): |
| Nominal Voltage (Vac) | 380/400/415Vac (3Ph+N+PE) |
| Bypass Voltage Range | Max. voltage: 220V: +25% (Optional +10%, +15%, +20%) 230V: +20% (Optional +10%, +15%) 240V: +15% (Optional +10%) Min. voltage: -45% (Optional -20%, -30%) |
| Power factor | >=0.99 |
| OUTPUT | |
| Voltage Range | 220/230/240Vac (L+N+PE) |
| Crest Factor | 3:1 |
| Harmonic distortion (THDv) | <=2% Linear Load <=5% Non Linear Load |
| Frequency Range | Line Mode: ±1%/±2%/±4%/±5%/±10% of the rated frequency (Optional) Battery Mode: (50/60 +0.1%) Hz |
| Overload | AC Mode : ≤110%,last 60min; ≤125%, last 10min; ≤150%, last 1 min; > 150% turn to bypass Immediately Battery Mode : ≤110%, last 10min; ≤125%, last 1min; ≤150%, last 5s; > 150% turn to bypass Immediately Breaker : 2*32A |
| Efficiency | up to 93.5% |
| Output waveform | Pure Sinewave |
| Voltage Regulation | ±1% |
| Output Transfer Time | AC mode to Bat.mode - 0ms Inverter to Bypass - 0 ms |
| Power Factor | 1.0 |
| PHYSICAL | |
| Approx. Net Weight | 33/125KG |
| Approx. Dimension (D×W×H) | Standard unit - 200 x 900 x 868 Long Run Unit - 250 x 580 x 655 |
| BATTERY | |
| Battery Voltage | Standard Unit : ±120Vdc (20 pcs 9Ah) (20 pcs 7Ah 2 x 20pcs 7/9Ah optional) Long Run Unit - ±96Vdc~±120Vdc (16~20pcs, 16pcs default, Standard unit and 20pcs no power derating; 18pcs output power factor 0.9; 16pcs output power factor 0.8) ±192/204/216/228/240Vdc (32/34/36/38/40pcs supportable) |
| Charging current (Max.) | Long Run Unit 14A Max Can set according to battery capacity installed |
| ENVIRONMENT | |
| Storage temperature | -25°C~55°C |
| Humidity range | 20~95%RH @ 0~40°C (Non condensing) |
| Noise level | <55dB at 1 meter |
| Altitude | <1500m, derating required when>1500m |
| Operating temperature | 0°C to 40°C |
| STANDARDS | |
| Safety | IEC/EN62040-1,IEC/EN62477-1 |
| EMC | IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 |