6-10 KVA, 1:1 | 10000VA / 9000W
Netcon 10 KVA Tower Type Online UPS is a state-of-the-art power protection solution designed to provide continuous, clean, and reliable power for critical devices. Built with True Online Double Conversion Technology, it ensures zero transfer time, making it ideal for sensitive equipment that cannot afford even a momentary power disruption. With CE and IEC Certification, Netcon UPS guarantees global safety and performance standard.
Key features include a high output power factor (0.9/1.0), ensuring maximum usable power, and multi-layered protection against overload, short circuits, surges, and fluctuations. The LCD display provides real-time system status, while communication ports (SNMP, RS232, USB) enable remote monitoring and control.Designed for high efficiency (up to 95%), it reduces power consumption and operating costs. The automatic bypass function ensures continuous power in case of UPS failure, while generator compatibility allows smooth operation with generator power.
This UPS is available in both Inbuilt Battery and External Battery configurations. The Inbuilt Battery model is a compact, plug-and-play unit best suited for short backup needs in offices, homes, and POS systems. On the other hand, the External Battery model offers extended backup by allowing the connection of additional battery banks, making it perfect for data centers, telecom, industrial automation, and healthcare environments
| Name | Certificate |
|---|---|
| LVD Certificate | View Certificate |
| EMC Certificate | View Certificate |
| CE Certificate | View Certificate |
| LVD Test Report | View Certificate |
| EMC Test Report | View Certificate |
| INPUT | |
|---|---|
| Voltage Range | 110 / 286Vac |
| Bypass frequency tracking range | Max.voltage: 230~264Vac Min.voltage: 176~220Vac |
| Power factor | >=0.99 |
| Nominal Voltage (Vac) | 208 / 220 / 230 / 240Vac |
| OUTPUT | |
| Efficiency | 93.5% |
| Overload | Line Mode : Load≤105% long time running; ≤125% last 10min; ≤130% last 30s; >130% turn to bypass mode immediately By pass mode : 63A (Breaker) |
| Output waveform | Pure Sinewave |
| Voltage Range | 208/220/230/240Vac |
| Frequency Range | Line mode : ±10% of the rated frequency Battery Mode : (50/60 (+/-) 0.1% Hz |
| Power Factor | 0.9 |
| Voltage Regulation | ±1% |
| Transfer time | AC mode to Bat.mode : 0ms Inverter to Bypass : 5 ms (Typical) |
| PHYSICAL | |
| Approx. Dimension (D×W×H) | H:191 x 460 x 337 ; S:191 x 460 x 720 (With wheel) |
| Approx. Net Weight | 71KG |
| BATTERY | |
| Battery Voltage | 240Vdc |
| Charging current (Max.) | 1A (Standard unit); Long run unit Max.current 8A (Charging current can be set according to battery capacity) |
| Capacity (Standard unit) | 9Ah /12V (7Ah/12V optional) |
| Typical recharging time | 6~8 hours (to 90% of full capacity) |
| ENVIRONMENT | |
| Humidity range (%) | 20~95%RH @ 0°C~40°C (Non condensing) |
| Noise level | <58dB at 1 Meter |
| Altitude | <1500m,derating required when>1500m |
| Storage temperature (ºC) | -25°C ~ 55°C |
| Operating temperature | 0°C~40°C |
| INDICATORS | |
| LCD Display (LCD version) | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time |
| LED Display (LED version) | Line mode, Bat.mode, ECO mode, Bypass mode, Battery low voltage, Overload & UPS fault |
| STANDARDS | |
| EMC | IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 |
| Safety | IEC/EN62040-1,IEC/EN62477-1 |
| FREQUENCY | |
| Frequency range | 40~70Hz (50/60Hz Auto-Sensing) |