Line Interactive UPS | Micropower 800
Netcon Line-Interactive UPS is specially designed for personal computers and versatile applications. Its lightweight, compact design makes it an ideal choice for environments with limited workspace. Equipped with one boost and one buck AVR, it ensures stabilized input voltage. The built-in DC start function allows the UPS to start even without an AC power supply, enhancing usability.
Line-Interactive UPS with simulated sinewave output provides seamless backup power during outages and protects against unsafe voltage fluctuations, surges, and spikes. Advanced microprocessor control, combined with internal self-diagnostic technology, guarantees excellent performance and high reliability.
Compliance & Standards
| MODEL | |
|---|---|
| Capacity | 800 VA/480 W |
| INPUT | |
| Operating voltage range (Vac) | 81~145 Vac/162~290 Vac |
| Operating frequency range (Hz) | 60/50Hz (Auto sensing) |
| Nominal Voltage (Vac) | 110/120 Vac or 220/230/240 Vac |
| OUTPUT | |
| Frequency Range | 60/50Hz ±1 Hz |
| Transfer time | Typical 2-6ms, 10ms Max. |
| Waveform | Simulated Sinewave |
| AC Voltage Regulation (Batt. Mode) (%) | ±10 |
| PHYSICAL | |
| Approx. Net Weight | 4.9 |
| EMC | IEC/EN 62040-2; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8 |
| Approx. Dimension (D×W×H) | 298×101×142 mm |
| Safety | IEC/EN 62040-1; IEC/EN 60950-1 |
| Performance | IEC/EN 62040-3 |
| BATTERY | |
| Battery Mode | Sounding every 10 seconds |
| Battery Voltage | 12Vdc |
| Typical recharging time | 4~6 hours recover to 90% capacity |
| Battery Type | 12 V/9Ah×1 |
| ENVIRONMENT | |
| Noise level (dB) | <45 |
| Humidity range (%) | 0 ~ 90 |
| INDICATORS | |
| LED Display (LED version) | AC Mode, Battery Mode, Overload, Fault |
| LCD Display (LCD version) | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Battery Low |
| Battery mode | Sounding every 10 seconds |
| Battery Replacement Alarm | Sounding every 2 seconds |
| Battery Fault | Continuously sounding |
| Overload | Sounding every 0.5 second |
| Low Battery | Sounding every second |
| OTHERS | |
| Protection | Overload, Breaker |
| SYSTEM FEATURES | |
| Communication interface | USB or RS232(Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC) |
| Overload | Sounding every 0.5 second |
| Protection | Short circuit, Overload, Overcharge and over discharge protection |
| Communication | USB or RS232(Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC) |