50-200 KVA 3:3 | 100KVA
Netcon 100 KVA Online 3-Phase UPS is a high-capacity, fully automated power backup system designed to provide stable, uninterrupted, and clean power to critical systems. Built with advanced true double-conversion technology, it ensures zero transfer time, isolating connected equipment from power fluctuations, surges, and outages. This UPS is the ideal choice for data centers, healthcare facilities, industrial automation, telecommunications, and other mission-critical environments where operational continuity is paramount. With CE and IEC Certification, Netcon UPS guarantees global safety and performance standard.
Netcon 100KVA Online 3-Phase UPS is a powerful, scalable, and energy-efficient backup power solution. With its true double-conversion technology, robust design, and modular scalability, it guarantees uninterrupted power to mission-critical systems. Its energy-efficient design, redundancy features, and advanced battery management make it the preferred choice for industries like IT, healthcare, telecommunications, and manufacturing. Its ability to operate in harsh environments ensures 24/7 uptime, making it a vital component for large-scale infrastructure and critical applications.
| Name | Certificate |
|---|---|
| EMC Certificate | View Certificate |
| LVD certificate | View Certificate |
| CE Certificate | View Certificate |
| EMC Test Report | View Certificate |
| LVD Test Report | View Certificate |
| INPUT | |
|---|---|
| Harmonic distortion (THDi) | <= 3% Linear load |
| Bypass Voltage Range | Max.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%) 240V:+15% (Optional+10%) Min.voltage:-45% (Optional-20%,-30%) |
| Frequency Range | 40~70Hz (50/60Hz Auto- Sensing) |
| Voltage Range | 138~485Vacfor40% load; 305~485Vac for full-load |
| Power factor | >= 0.99 |
| Frequency Protection Range | 50/60Hz±10% |
| Nominal Voltage (Vac) | 380/400/4 15Vac (3Ph+N+PE) |
| Generator Input | Input |
| OUTPUT | |
| Voltage Regulation | ±1% |
| Power Factor | 1.0 |
| Crest Factor | 3:1 |
| Harmonic distortion (THDv) | <= 2% with linear load <= 4% with non linear load |
| Frequency Range | Line Mode: ± 1%/ ± 2%/ ± 4%/ ± 5%/ ± 10% of the rated frequency (Optional) Battery Mode - (50/60 ±0.2%)Hz |
| Overload | AC Mode : Load «110%: last 60min, «125%: last 10min, «150%: last 1min, >150%:turn to bypass immediately By Pass Mode : 135% overload long time; >1000% overload 100ms |
| Voltage Range | 380/400/4 15Vac (3Ph+N+PE) |
| PHYSICAL | |
| Approx. Dimension (D×W×H) | 442x850x1200 |
| Approx. Net Weight | 160KG |
| BATTERY | |
| Charging current (Max.) | 40A Max. (charge current can be set according to battery capacity installed |
| Battery Voltage | Optional Voltage: ± 180/ ± 192/ ± 204/ ± 216/ ± 228/ ± 240/ ± 252/ ± 264/ ± 276/ ± 288/ ± 300Vdc(30/32/34/36/38/40/42/44/ 46/48/50pcs optional); 360Vdc~600Vdc (30~50pcs, 30pcs default, 36~50pcs output power factor 1.0; 32~34pcs output power factor 0.9; 30pcs output power factor 0.8) |
| ENVIRONMENT | |
| Storage temperature | 250 -550 (No battery) |
| Operating temperature | 0°C~40C |
| Humidity range | 0-95% (Non condensing) |
| Noise level | <62dB |
| Altitude | <1500m, derating required when>1500m |
| EFFICIENCY | |
| Efficiency | Up to 95.5% |
| STANDARDS | |
| Safety | IEC/EN62040-1, IEC/EN62477-1 |
| EMC | IEC/EN62040-2 (IEC 61000-2-2, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11) |
| SYSTEM FEATURES | |
| Communication | USB, RS232, RS485, parallel port, dry contact, intelligent slot, LBS, SNMP card (Optional), relay card (Optiona) |
| Protection | Short circuit, overload, over temperature, battery low, fan fault alarm |
| Transfer time | Utility to Battery: 0ms; Utility to Bypass: 0ms |
| Backfeed protection | Support |
| Remote LCD | Support |
| Alarm | Overload, utility abnormal, UPS fault, battery low, etc |