50-200 KVA 3:3 | 120KVA
Netcon 120 KVA Online 3-Phase UPS is a high-capacity, fully automated power backup system designed to provide stable, uninterrupted, and clean power to critical systems. Built with advanced true double-conversion technology, it ensures zero transfer time, isolating connected equipment from power fluctuations, surges, and outages. This UPS is the ideal choice for data centers, healthcare facilities, industrial automation, telecommunications, and other mission-critical environments where operational continuity is paramount. With CE and IEC Certification, Netcon UPS guarantees global safety and performance standard.
Netcon 120KVA Online 3-Phase UPS is a powerful, scalable, and energy-efficient backup power solution. With its true double-conversion technology, robust design, and modular scalability, it guarantees uninterrupted power to mission-critical systems. Its energy-efficient design, redundancy features, and advanced battery management make it the preferred choice for industries like IT, healthcare, telecommunications, and manufacturing. Its ability to operate in harsh environments ensures 24/7 uptime, making it a vital component for large-scale infrastructure and critical applications.
| Name | Certificate |
|---|---|
| LVD certificate | View Certificate |
| EMC Certificate | View Certificate |
| CE Certificate | View Certificate |
| LVD Test Report | View Certificate |
| EMC Test Report | View Certificate |
| INPUT | |
|---|---|
| Harmonic distortion (THDi) | <= 3% Linear load |
| Generator Input | Input |
| Nominal Voltage (Vac) | 380/400/4 15Vac (3Ph+N+PE) |
| Frequency Protection Range | 50/60Hz±10% |
| Frequency Range | 40~70Hz (50/60Hz Auto- Sensing) |
| Voltage Range | 138~485Vacfor40% load; 305~485Vac for full-load |
| Bypass Voltage Range | Max.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%) 240V:+15% (Optional+10%) Min.voltage:-45% (Optional-20%,-30%) |
| Power factor | >= 0.99 |
| OUTPUT | |
| Overload | AC Mode : Load «110%: last 60min, «125%: last 10min, «150%: last 1min, >150%:turn to bypass immediately By Pass Mode : 135% overload long time; >1000% overload 100ms |
| Crest Factor | 3:1 |
| Power Factor | 1.0 |
| Harmonic distortion (THDv) | <= 2% with linear load <= 4% with non linear load |
| Voltage Regulation | ±1% |
| Frequency Range | Line Mode: ± 1%/ ± 2%/ ± 4%/ ± 5%/ ± 10% of the rated frequency (Optional) Battery Mode - (50/60 ±0.2%)Hz |
| Voltage Range | 380/400/4 15Vac (3Ph+N+PE) |
| PHYSICAL | |
| Approx. Net Weight | 170KG |
| Approx. Dimension (D×W×H) | 442x850x1200 |
| BATTERY | |
| Charging current (Max.) | 40A Max. (charge current can be set according to battery capacity installed |
| Battery Voltage | Optional Voltage: ± 180/ ± 192/ ± 204/ ± 216/ ± 228/ ± 240/ ± 252/ ± 264/ ± 276/ ± 288/ ± 300Vdc(30/32/34/36/38/40/42/44/ 46/48/50pcs optional); 360Vdc~600Vdc (30~50pcs, 30pcs default, 36~50pcs output power factor 1.0; 32~34pcs output power factor 0.9; 30pcs output power factor 0.8) |
| ENVIRONMENT | |
| Humidity range | 0-95% (Non condensing) |
| Noise level | <62dB |
| Operating temperature | 0°C~40C |
| Storage temperature | 250 -550 (No battery) |
| Altitude | <1500m, derating required when>1500m |
| EFFICIENCY | |
| Efficiency | Up to 95.5% |
| STANDARDS | |
| EMC | IEC/EN62040-2 (IEC 61000-2-2, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11) |
| Safety | IEC/EN62040-1, IEC/EN62477-1 |
| SYSTEM FEATURES | |
| Backfeed protection | Support |
| Protection | Short circuit, overload, over temperature, battery low, fan fault alarm |
| Communication | USB, RS232, RS485, parallel port, dry contact, intelligent slot, LBS, SNMP card (Optional), relay card (Optiona) |
| Remote LCD | Support |
| Transfer time | Utility to Battery: 0ms; Utility to Bypass: 0ms |
| Alarm | Overload, utility abnormal, UPS fault, battery low, etc |