10-40 KVA 3:3, 3:1 | 10KVA / 9KW or 10KW
Netcon 10 KVA 3:3 Phase Tower Mount Online UPS is a high-capacity, industrial-grade power backup system designed for large-scale critical applications. With a 3-phase input and 3-phase output configuration, it ensures balanced power distribution, high efficiency, and continuous protection for mission-critical systems in data centers, healthcare, telecom, and industrial operations. UPS is CE Certified and fully compliant with EMC & IEC safety and performance standards, ensuring global compatibility, safety, and reliability.
Powered by True Online Double Conversion Technology, it delivers uninterrupted, pure, and stable power with zero transfer time, ensuring complete protection against power fluctuations, surges, and blackouts. The External Battery Type design allows for the connection of scalable battery banks, offering customizable and extended backup times to meet specific operational needs. Its advanced protection features, high efficiency (up to 95%), and scalable runtime make it a trusted power solution for industries where power continuity is critical.
This UPS offers customizable backup duration, flexible battery expansion, and smart remote monitoring, making it a versatile choice for large-scale, power-intensive applications in data centers, healthcare, telecom, industrial automation, and commercial buildings.
| Name | Certificate |
|---|---|
| EMC Certificate | View Certificate |
| LVD Certificate | View Certificate |
| EMC Test Report | View Certificate |
| LVD Test Report | View Certificate |
| MODEL | |
|---|---|
| Capacity | 10KVA / 9KW or 10KVA / 10KW |
| INPUT | |
| Bypass Voltage Range | Max. voltage: 220V: +25% (Optional +10%, +15%, +20%) 230V: +20% (Optional +10%, +15%) 240V: +15% (Optional +10%) Min. voltage: -45% (Optional -20%, -30%) |
| Harmonic distortion (THDi) | <=3% Linear load |
| Voltage Range | 305-478 VAC (Full load): 208-478 VAC (50% load): |
| Nominal Voltage (Vac) | 380/400/415Vac (3Ph+N+PE) |
| Power factor | >=0.99 |
| Frequency Range | 40-70Hz (50/60Hz Auto Sensing) |
| ECO Range | Same as bypass |
| Frequency Protection Range | 50/60Hz±10% |
| OUTPUT | |
| Efficiency | up to 93.5% |
| Output waveform | Pure Sinewave |
| Voltage Regulation | ±1% |
| Power Factor | 0.9 |
| Voltage Range | 380/400/415Vac (3Ph+N+PE) |
| Crest Factor | 3:1 |
| Harmonic distortion (THDv) | <=2% Linear Load <=5% Non Linear Load |
| Frequency Range | Line Mode: ±1%/±2%/±4%/±5%/±10% of the rated frequency (Optional) Battery Mode: (50/60 +0.1%) Hz |
| Output Transfer Time | AC mode to Bat.mode - 0ms Inverter to Bypass - 0 ms |
| Overload | AC Mode : ≤110%,last 60min; ≤125%, last 10min; ≤150%, last 1 min; > 150% turn to bypass Immediately Battery Mode : ≤110%, last 10min; ≤125%, last 1min; ≤150%, last 5s; > 150% turn to bypass Immediately |
| PHYSICAL | |
| Approx. Dimension (D×W×H) | Standard unit - 200 x 900 x 868 Long Run Unit - 250 x 580 x 655 |
| Approx. Net Weight | 129/35KG |
| BATTERY | |
| Charging current (Max.) | Standard Unit : 1.35A (2.7A Optional) Long Run Unit 14A Max Can set according to battery capacity installed |
| Battery Voltage | Standard Unit : +120Vdc (20pcs 12V9Ah) (20pcs 12V7Ah, 2x20pcs 12V7/9Ah optional) Long Run Unit - 10-30kVA: +96/108/120Vdc; battery quantity(16~20pcs, 16pcs default, Standard unit and 20pcs no power derating: 18pcs output power factor 0.8/0.9;16pcs output power factor 0.7/0.8) +180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs supportable) |
| ENVIRONMENT | |
| Noise level | <55dB |
| Storage temperature | -25°C~55°C |
| Operating temperature | 0°C to 40°C |
| Altitude | <1500m, derating required when>1500m |
| Humidity range | 20~95%RH @ 0~40°C (Non condensing) |
| STANDARDS | |
| EMC | IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 |
| Safety | IEC/EN62040-1,IEC/EN62477-1 |